PIC16(L)F1782/3
DS41579C-page 390
Preliminary
2011-2012 Microchip Technology Inc.
TABLE 30-14: EUSART SYNCHRONOUS RECEIVE REQUIREMENTS
Standard Operating Conditions (unless otherwise stated)
Operating Temperature
-40°C
TA +125°C
Param.
No.
Symbol
Characteristic
Min.
Max.
Units
Conditions
US125 TDTV2CKL SYNC RCV (Master and Slave)
Data-hold before CK
(DT hold time)
10
—
ns
US126 TCKL2DTL Data-hold after CK
(DT hold time)
15
—
ns